| TM 11-6625-847-12
Control, indicator, or connector
Function
FREQ STANDARD OUTPUT AMPL switch (2) ---------
Controls input to amplifier modules AR1 and AR2.
Pos
Action
--------------------------------------------------------------------
ON
Input amplified.
--------------------------------------------------------------------
OFF
Amplifier bypassed.
MC SYNTH OUTPUT AMPL switch -----------------------
Controls input to amplifier module AR3.
Pos
Action
--------------------------------------------------------------------
ON
Input amplified.
--------------------------------------------------------------------
OFF
Amplifier bypassed.
FREQ SELECT 1KC 10KC and controls -----------------
Controls, mechanically, position of 10-ke and 1-kc shaft
FREQ SELECT 1OOKC control ----------------------------
Controls, mechanically, position of 100-kc shaft couplers.
POWER ADJ control -----------------------------------------
Controls level of de variable supply voltage.
10&1KC SYNTH SYNTH OUTPUTS VOLTS ADJ------
Controls output level of amplifier AR4.
control.
10&1KC SYNTH OUTPUT VOLT ADJ control ----------
Controls output level of amplifier AR5.
FREQ STANDARD OUTPUT VOLT ADJ control -------
Controls output level of amplifiers AR1 and AR2.
(2).
MC SYNTH OUTPUT VOLT ADJ control ----------------
Controls output level of amplifier AR3.
POWER indicator ----------------------------------------------
Indicates POWER switch S1 is set to ON, and +27 volts de is
supplied to test tray from test set.
MC SYNTH HI indicator ---------------------------------------
Indicates selection of high band of frequencies.
MC SYNTH LO indicator -------------------------------------
Indicates selection of low band of frequencies.
J1 -------------------------------------------------------------------
Multipin connector for electrical interconnection of tray A3 and
test set.
POWER INPUTS FIXED test connector ---------------
Test point for measurement of fixed +20-volt dc supply.
POWER INPUTS VAR test connector -------------------
Test point for measurements of variable +20-volt dc supply.
POWER INPUTS (ground) test connector ---------------
Ground test point for measurement of input voltage.
FREQ STANDARD 5MC EXT/INT connector ----------
For connecting test equipment to frequency standard module,
RT662/GRC at J7.
FREQ STANDARD OUTPUT 1MC connector ----------
For monitoring 1-mc output of frequency standard module,
RT-62/GRC.
FREQ STANDARD module connector --------------------
Multipin connector for electrical interconnection of frequency
standard module, RT-662/GRC, and tray A3.
FREQ STANDARD module connector --------------------
Multipin connector for electrical interconnection of frequency
standard module, RT62/GRC, and tray A3.
MC SYNTH module connector ----------------------------
Multipin connector for electrical interconnection of me
synthesizer module, RT-662/GRC, and tray A3.
FREQ DIVIDER OUTPUTS 1OOKC SPECTRUM------
For monitoring the 100-kc spectrum output of fre-
connector -------------------------------------------------------
quency divider module RT-662/GRC.
FREQ DIVIDER OUTPUTS 1.75MC connector ---------
For monitoring the 1.75-me output of frequency divider
module, RT-462/GRC.
FREQ DIVIDER module connector -----------------------
Multipin connector for electrical interconnection of frequency
divider module, RT462/GRC and tray A3.
FREQ DIVIDER module connector ------------------------
Multipin connector for electrical interconnection of frequency
divider module, RT-662/GRC, and tray A3.
FREQ DIVIDER OUTPUTS 1KC PULSE -----------------
For monitoring 1-kc pulse output of frequency di-
connector -------------------------------------------------------
vider module, RT-662/GRC.
FREQ DIVIDER OUTPUTS O1KC SPECTRUM -------
For monitoring 10-kc spectrum output of frequency
connector -------------------------------------------------------
divider module, RT-662/GRC.
FREQ STANDARD OUTPUT 10MC connector ---------
For monitoring 10-me output of frequency standard module,
RT-662/GRC.
MC SYNTH OUTPUT MC SYNTH connector ----------
For monitoring rf output of me synthesizer module, RT-
662/GRC.