| TM 11-6625-847-12
Control, indicator, or connector
Function
Pos
Action
PA/RT switch ----------------------------------------------------
PA ------------- Provides five-wire coding information, frequency
change ground, frequency information ground,
and ALC VOLTAGES test points; TUNE IN
and INFO IN are connected to PA CONTROL
connector J12.
RT ------------- Provides inputs on PA CONTROL connector
pins connected to J1, ALC VOLTAGE INFO,
and TUNE test points OUT and ALC control
voltages; ALC VOLTAGE INFO and TUNE
are connected to PA CONTROL connector
J12.
POWER indicator -----------------------------------------------
Indicates POWER switch S2 is set to ON, and +27volt dc
primary power is supplied from external source.
ALC VOLTAGE INFO control --------------------------------
Adjusts level of dc voltage at test point ALC VOLTAGE INFO
OUT and to PA/RT switch contact terminal 4, section D.
ALC VOLTAGE TUNE control -------------------------------
Adjust level of dc voltage at test point ALC VOLTAGE TUNE
OUT and to PA/RT switch contact terminal 1, section C.
DC VOLTAGE 200 control -----------------------------------
Adjusts level of +200-volt de output voltage.
DC VOLTAGE 20 control --------------------------------------
Adjusts level of +20-volt dc output voltage.
IF OSCILLATORS 1 1.75 MC output level control -----
Adjusts 1.75-me RF output level of IF oscillator module.
IF OSCILLATORS 2 1.7515 MC output level control --
Adjusts 1.7515-mc RF output level of IF oscillator module.
IF OSCILLATORS 3 1.7525 MC output level control --
Adjusts 1.7527-mc RF output level of IF oscillator module.
PULSE GENERATOR (upper) AMPLITUDE
Controls amplitude of this 85-sec pulse, and 150-sec
control.
pulse at OUTPUT connectors 1 and 2, respectively.
PULSE GENERATOR (upper) WIDTH control -------
Controls width of output pulse to 85-sec at connector
PULSE GENERATOR (lower) AMPLITUDE--------------
1, or to 150-sec at connector 2.
control.
Controls amplitude of 1-sec pulse at connector 3.
PULSE GENERATOR (lower) WIDTH control ---------
Controls width of 1-sec pulse at connector 3.
10 AMP fuse -----------------------------------------------------
Current protection for test set.
SPACE fuse ------------------------------------------------------
Receptacle for storage of spare fuse.
IF OSCILLATOR 4 TWO TONE output level control --
Adjust RF output level of mixer assembly.
POWER connector --------------------------------------------
Multipin connector for power cable W15.
DC VOLTAGE (ground) test connector -------------------
Ground test point for dc voltage measurements.
DC VOLTAGE +200 test connector -----------------------
Test point for measuring +200 volts dc.
AUDIO IN/OUT connector ------------------------------------
Multipin connector for audio cable W12.
AUDIO IN 600 (ohm) connector -----------------------------
For connecting external audio test equipment to AUDIO
IN/OUT connector.
AUDIO IN (ground) connector -------------------------------
Ground connector for external audio test equipment at AUDIO
IN/OUT connector.
AUDIO IN 50 (ohm) connector ------------------------------
For connecting external audio test equipment to AUDIO
IN/OUT connector.
AUDIO OUT 2 WATT connector ----------------------------
Connector for measuring audio input signals at AUDIO
IN/OUT connector.
AUDIO OUT (ground) connector ----------------------------
Ground connection for measuring audio input signals at
AUDIO IN/OUT connector.
AUDIO OUT 10 MW connector ----------------------------
Connector for measuring audio input signals at AUDIO/OUT
connector.
DC VOLTAGE +20 test connector -------------------------
Test point for measuring +20 volts de.
PA CON'TROL connector ------------------------------------
Multipin connector for control cable W11.