| 3-6 Battery Charging Procedure
The battery power supply batteries can be recharged to a certain level without removing them from the battery power
supply case. Either a 115 Vac (105 to 1 25V) or + 28 V (22 to 30V) source can be used to recharge the batteries. The
battery supply can be either attached to or removed from the R/T unit while the batteries are charging. To recharge the
batteries, proceed as follows.
a. Connect the battery case power input terminal to a source of charging power as shown in Figure 3-2. Use
the cable supplied with the battery power supply for this purpose.
NOTE
The R/T unit will not operate properly when charging the supply from a 115 Vac
source. The R/T unit will operate properly when charging from a +28 V source.
b. Allow the battery supply to charge to the proper level. When using the 115 Vac source, the batteries will be
charged to 70 percent full charge in 40 hours. When using the 28 V source. the batteries will be charged to
80 percent full charge in 16 hours.