| a. Manual Frequency Selection. To select and operate on a frequency other than one stored in memory, refer
to Figure 2-5 and perform the following steps:
(1) Position SCAN switch (4) to OFF.
(2) Position PWR switch (5) to up position, then verify PWR indicator is on
(3) Position frequency channel selector switch
(3) to MAN position.
(4) Beginning with left-most digit, press and release left-most frequency selector push- button (7) until
desired number is indicated in window above the switch (8).
(5) Repeat step 4 for each of the remaining numbers of the selected frequency moving right to the next digit
and switch for each new digit.
NOTE
The last two digits must be either 00,
25, 50, or 75 and are located on the
right-most switch and indicator.