| TM 11-5895-1141-34
Table 4-17. MODULE TEST SET, SPEAKER AMPLIFIER TEST
Step
Operation
Normal Indication
1
All module test set controls must be preset
according to the procedure in
paragraph 4-10.
2
Set METER SCALE switch to the 1.1 v/O dB
position. With the 600 Ω DUMMY LOAD switch
to IN, set the OSCILLATOR LEVEL to 0 dBm.
3
Set the 20 dB ATTENUATOR switch to IN; the
INPUT SELECTOR switch to RCVR AUDIO; the
OUTPUT SELECTOR switch to LOUDSPEAKER; the
METER SCALE switch to 3.5 v/10 dB. Set the
600 Ω DUMMY LOAD switch to OUT position.
4
Set the SPEAKER/HEADSET switch on the
selector module to the SPEAKER position.
5
Turn SPEAKER VOLUME control on volume
A meter reading of 1.1 v minimum should be
control module to full CW position.
obtained.
Turn 3.2 Ω DUMMY LOAD switch on test set to
A clear tone should be heard.
the SPEAKER position.
6
All switches and controls on test set
should be returned to the initial positions
specified in paragraph 4-10.
4-48
|