| TM 11-5895-1141-34
Table 4-15. MODULE TEST SET, SELECTOR MODULE TEST (Cont'd)
Step
Operation
Normal Indication
b. Turn LOCK/NONLOCK switch to off. Turn
test set P/T KEY and INTERLOCK switches to
OFF. Return 3.2 Ω DUMMY LOAD switch to
3.2 Ω. position.
6
Set METER SCALE to 0.11 v/-20 dB, INPUT
The amber lamp (DS1002) on selector module
SELECT switch to RCVR AUDIO and OUTPUT
should have a perceptible glow. If not
SELECT switch to OSCILLATOR. Adjust
Perceptible adjust R1003, the threshold
OSCILLATOR LEVEL to 0.042 v.
adjust potentiometer until the lamp just
glows.
7
Set METER SCALE to 1.1 v/O dB. Adjust
DS1002 should now glow brightly.
OSCILLATOR LEVEL to 0.424 v.
Rapidly operate the INTERNAL/EXTERNAL
The lamp should flash at a corresponding
switch back and forth on the test set.
rate.
8
Set METER SCALE to 0.35 v/-10 dB. Adjust
OSCILLATOR LEVEL to 0.134 v. Set both
levels of the volume control fully CW.
Meter should read 0 1 dBm.
Set OUTPUT SELECT switch to HEADSET and
METER SCALE to 1.1 v/O dB. Place HEADSET/
SPEAKER switch on selector module to
HEADSET.
4-44
|