| TM 11-5895-1141-34
Table 4-14. MODULE TEST SET, VOLUME CONTROL MODULE TEST (Cont'd)
Step
Operation
Normal Indication
Meter should read -25 dBm 2 dBm (sidetone
8
Set the METER SCALE 0.11 v/-20 dB and the
OUTPUT SELECT switch to HEADSET. Set the
signal).
LOCK/NONLOCK switch on the selector module
to the LOCK position and the P/T KEY switch
to ON.
9
Turn P/T KEY switch to OFF and then the
INTERLOCK switch to ON. Set the
3.2 Q DUMMY LOAD switch to SPEAKER and the
METER SCALE to 3.5 v/+10 dBm.
10
Turn the P/T KEY switch to ON.
Busy tone should be heard on the loudspeaker
and a reading should be observed on the
meter.
11
All switches and controls should be
Busy tone should be heard on the loudspeaker
returned to the initial positions specified
and a reading should be observed on the meter.
in paragraph 4-10.
4-42
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |