TM 11-5895-1141-34
o.
HEADSET VOLUME control fully CCW
p.
LOCK/NONLOCK switch (on selector module) OFF
q.
SPEAKER/HEADSET switch (on selector module) OFF
The module test adapter is shown in figure 4-13. This unit functions as a module extender permitting operation of any
module with the circuit board exposed to facilitate testing and troubleshooting.
4-11.
TURN-ON AND PRELIMINARY CHECKS
a.  Turn the POWER switch on. The adjacent power indicator should light up. Except for dim backlight glow in the
selector module indicator lamps, no other lamps should be on nor should any reading be present on the meter.
b.  Press the PRESS TO READ 24 v switch and verify that the meter reads 24 volts 0.6 volts. Position the 24
VDC SUPPLY VOLTAGE ADJ. if necessary.