| TM 11-5895-1141-34
Table 4-4. VOLTAGE MEASUREMENTS, VOLUME CONTROL ASSEMBLY
Location
Condition of Operation
Voltage
+24 2 v
C11001 to E3
Any
+12 0.6 v
C1105 to E3
Any
NOTE
Refer to figure FO-9 for component locations.
Table 4-5. VOLTAGE MEASUREMENTS, SELECTOR MODULE ASSEMBLY
Location
Condition of Operation
Voltage
+24 2 v
Q1007 collector to E12
Any
+24 2 v
E7 TO E8
Any
23.5 2 v
Q1008 collector to E2
Channel Unkeyed
0.5 0.3 v
Q1008 collector to E2
Channel Keyed
23.5 2 v
E11 to E12
Channel Unkeyed
0.5 0.3 v
E11 to E12
Channel Keyed
0.5 0.3 v
Q1009 collector to E12
Channel Keyed after Keying
at Position
23.0 2 v
Q1009 collector to E12
Channel Unkeyed
23.0 2 v
Q1009 collector to E12
Channel Keyed Before Keying
at Another Position
NOTE
Refer to figure FO-7 for component locations.