| TM 11-5826-258-24
VOR/LOC receiver sensitivity at following fre-
Control
quencies:
1000
MOD. SELECTOR
108.00
111.30
114.60
117.90
FREQUENCY RANGE (selector) D
112.40
109.10
115.70
117.95
Desired frequency. Use
FREQUENCY
110.20
113.50
116.80
AN/USM-207 to set fre-
(1) Check to see that there is audio output present
quency within 1 Khz.
on the TS-585/U.
Peak on meter
AMP. TRIMMER
(2) Set the Output Attenuator control on the
SET LEVEL (red arrow)
OUTPUT LEVEL
AN/USM-44 for an indication of 5 microvolt on the
MOD LEVEL
OUTPUT VOLTS-DBM indicator.
b. Procedure. In the following procedure 108.00
(3) Note the indication on the TS-585/U meter.
megahertz is used as an example of a selected fre-
( 4 ) Turn the MOD. SELECTOR on the
quency; therefore, set the CONTROL frequency on the
AN/USM-44 to CW.
AN/ARM-92B to 108.00 Hz. Set the FREQUENCY
(5) The indication on the TS-585/U meter shall be
control to 108.00 megaHertz using the AN/USM-207
at least 6 db less than the indication in (3) above.
to set within 1 KHz. Use this procedure to check
3-20
|