Section Il. MAINTENANCE ALLOCATION CHART FOR
AN/ARC-201(V) AND AN/ARC-201A(V)
(1)
(2)
(3)
(4)
Maintenance Category
(5)
(6)
Group
Component/Assembly
Maintenance
Tools and
Remarks
Number
Function
AVUM
AVIM
DEPOT Equipment
0602
Electronic
D
Component Assy
(3A2)
0603
Control, CCM
D
Electronic (3A3)
0604
CCA, Interface
D
(3A4)
0605
CCA, Switching
D
(3A5)
0606
IF/Demodulator
D
(3A6)
0607
Tuner/Mixer
D
(3A7)
0608
Synthesizer,
D
Elec Freq
(3A8)
0609
Amplifier-
D
Oscillator (3A9)
0610
Power Supply
D
Assy (3A10)
0611
Chassis, Elec
D
Equipment
(3A11)
07
Control, Radio Set
Inspect
0.1
C-11466/ARC-201(V)
Inspect
0.1
(Unit 4)
Test
0.1
1,2
Test
0.1
3,4,7,9,10
Install
0.1
1
Replace
0.1
1
Repair
0.1
1,2
B
Repair
0.2
3,4,7,9,10
0703
CCA-Processor (4A3)
Inspect
0.1
Test
0.1
11,23
Replace
0.1
9
Repair
0.5
9,11,14,
15,23
B-20
|