Page Title: Figure 6-3. Control Panel A1A4 Performance Test Setup
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5820-919-40-2
Figure 6-3. Control Panel A1A4 Performance Test Setup
SPECIAL TOOLS, MATERIALS, AND FABRICATED TEST CABLES AND FIXTURES
Description
Part Number
Reference
Kit, Tool, Electronic
TK-100/G
None
Bench Repair Center
Pace PRC-350C
None
Maintenance Kit, Printed Circuit
MK-984/A
None
TEST EQUIPMENT
Name
Designation
Quantity
Radio Set, Test Bed
AN/PRC-104
1
CAUTION
Digital Multimeter
AN/USM-341
1
TO AVOID DAMAGE TO THE BENCH
(DVM, ohmmeter function)
TEST CABLE RADIO PROTECTION
CIRCUITS APPLY POWER AS
FOLLOWS:
Power Supply, DC
Hewlett Packard HP-6439B
1
1. CONNECT BENCH TEST CABLE
TO RADIO.
2. TURN ON POWER SUPPLY AND
CHECK OUTPUT LEVEL.
3. THEN CONNECT BENCH TEST
CABLE TO POWER SUPPLY.
NOTES:
1. EQUIVALENT TEST EQUIPMENT MAY BE USED.
2. USE ONLY TEST EQUIPMENT THAT IS PROPERLY
CALIBRATED. FAILURE TO DO SO MAY PROVIDE
ERRONEOUS OR MISLEADING PERFORMANCE OF FAULT
INDICATIONS.