NOTES: UNLESS OTHERWISE SPECIFIED
1. PARTIAL REF DESIGNATIONS ARE
SHOWN FOR COMPLETE DESIGNATION PREFIX
WITH A1A2
2. CAPACITANCE VALUES ARE IN PICOFARADS
+5%, 500V
3. INDUCTOR RESONANT FREQ.
ARE IN MEGAHERTZ (MHz).
4
ALL RELAYS EXCEPT FOR FL1-K ARE
SHOWN DE-ENERGIZED.
5. INDICATES DEPENDENCY ON BENCH
POWER SUPPLY VOLTAGE
6. VOLTAGES IN TRANSMIT MOOD WITH 50 OHM
RADIO SET LOAD, RF OUTPUT 20W
7
FOR SIGNAL INPUT/OUTPUT
ROUTING REFER TO FIGURE 2-1