Page Title: INTRODUCTION
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5820-919-40-2
INTRODUCTION
This technical manual provides maintenance prints for Radio Set ANtPRC-104 (radio set). It is used in conjunction with the general instructions, maintenance information, and theory contained with the general instructions, maintenance information, and theory
contained in TM 11-5820-919-40-1. For parts ordering information refer to TM 11-5820-919-24P
Maintenance prints are provided for the radio set; the receiver/exciter unit and its 5 modules; and the amplifier/coupler unit and its 2 modules. The maintenance prints radio set and the two units are the same as those contained in TM 11-5820-919-40-lo The
maintenance prints include schematics, power distribution; component location; test and alignment setup; performance test; and alignment procedures.
Schematic diagrams contain pertinent voltage and waveform reference data to assist in fault isolation and are used an conjunction with the performance test flowcharts.
Component location diagrams locate and list every replaceable component, and identify the location of test points and pins required to monitor voltages and waveforms on performance test flowcharts.
Test and alignment setup diagrams provide a list of test equipment, a list of special tools and materials, fabricated cables and fixtures, and initial connections for the test setup, They are used in conjunction with the performance test flowcharts. Module
performance tests may be performed more easily if the module is tested while inside the radio set, rather than extended via cables. Once a fault is indicated, the module should be removed from the radio set and connected via appropriate extender cables.
Performance test flowcharts provide performance test (heavy flow line) and troubleshoot mug procedures (light flow line) for fault isolating to a component or group of components. The flowcharts are supported by the reference information provided in the
other diagrams.
Alignment procedures are used in conjunction with the performance test flowcharts.
NOTE
Poor electrical connection due to dirty or bent connector plus may often be the cause of equipment malfunction or faulty test indication. All electrical connections should be double-checked before proceeding with test or fault isolation.
TECHNICAL CHARACTERISTICS
Characterlstlc
Description
Characteristic
Description
Characteristic
Description
RADIO SET AN/PRC-104 (Radio Set)
Power Requirements
20.0 to 32.0 vdc with input at 3.5 amp
Audio Distortion
5 percent at 5 mw, 350 to 3000 Hz
2.5% to -29 dbm;
Frequency Range
2.0000 to 29.9999 MHz in. 0.0001 MHz
(24 vdc) for transmit (typical). 200 ma
Desensitization (signal to
(100 Hz) increments (280,000 possible
for receive (typical).
10% to -15 dbm;
degrade SINAD 3 db)
frequency settings)
Operating Temperature Range
-51 (-46 ) to +160 (+71 )
F
C
F
C
50% to +17 dbm
1 ppm for -51 (-46 ) to +160 (+71 )
Environmental
Meets applicable provisions of MIL-
Frequency Accuracy
F
C
F
C
STD-810B
(2 to 30 Hz of setting) from 2 to 30 MHz
RF Output Power
0.3 W (PEP) for RT-1209, 20W (PEP or
Mean Time Between Failure (MTBF) 2500 hours (demonstrated per MIL-
respectively.
average) with AM-6874
STD-785)
Operating Modes
- Slngle sideband (selectable USB or LSB)
Intermodulation Distortion (IMD)
-25 db (two equal tones at rated output
Mean Time to Repair (MTTR)
15 minutes (module replacement)
- Voice/cw (Morse or burst cw at 300 wpm)
power
Dimensions
12 1/2 x 10 1/2 x 2 5/8 (31.75 cm x
- Data (FSK or DPSK up to 2400 bps) compatible
-50 db
26.67 cm x 6.66 cm) D x U x H
with 75 baud military teletype
Carrier Suppression
-42 db
Weight
14 pounds (6.36 Kg), including 4.8 AN
- Receive only (inhibits transmit operation)
Unwanted Sideband Suppression
-45 db
silver zinc battery (without
Audio Input Impedance
150 ohms, -56 dbm (voice) or, 6 mv. RMS.
All Other Spurious
-45 to -60 db
accessories)
and Level
600 ohms, 0 dbm (data) or, 77 v. RMS,
Duty Cycle
1 minute continuous keydown, 9:1
RECEIVER
RP Output Power
20w (PEP), 0.25w (PEP) exciter output
transmit/receive ratio
Sensitivity
RF Output Impedance
50-ohms, unbalanced. Output protected to
BATTERY PACK
SSB, Cal, FSK
0.7 v for 10 db SINAD (-110 dbm
infinite VSWR due to antenna short or open.
Battery
Silver-zinc (AgZn), rechargeable 4.8 AH
voice, -70 dbm data)
Antenna Tuning
Automatic to 1.5:1 VSWR (3 seconds
Selectivity
2.5 kHz Bandwidth at -3 db
tuning time, typical)
SSB, CW, FSR
6.0 kHz Bandwidth at -60 db
Image Rejection
70 db
I.F. Rejection
60 db
Audio Output
25 tow into 500 (nominal)
1