|
| TM 11-5820-918-13
Table 3-1.
Controls and Indicators - Continued
Figure
Function
Control
reference
BLKR STORE
When actuated, causes the frequency set on
11.
Pushbutton Switch
BLANKER FREQ switches to be stored in memory
channel selected by CHANNEL Switch. This
switch is enabled only with PROG/RUN switch in
PROG position.
When actuated, enables readout on MHz frequency
12.
BLKR DSPL
display of blanker frequency from memory of
Pushbutton Switch
selected CHANNEL, providing PROG/RUN switch
is in PROG position. If PROG/RUN switch is in RUN
position, erroneous display of memory can occur.
On/Off control for battery circuit of timer auxil-
BAT ON/OFF
13.
iary power supply.
Switch
NOTE
In all Operational modes, the BAT ON/OFF switch should be left on.
When on, battery control of the timer becomes automatic in the event
of a main AC line power failure.
14.
PROG/RUN
A two-position toggle switch that controls the
frequency blanking function. In PROG position,
Switch
the blanker memory may be loaded or checked, and
frequency blanking is disabled during a sweep. In
RUN position, the memory frequency settings will
automatically blank the transmitter output as
described in 9 above.
A two-position, locking-type toggle switch that
DIPLEX/DIRECT
15.
selects the transmitter output connection. The
Switch
toggle lever is spring-loaded to lock and must be
pulled out to change switch positions. In DIPLEX
position, TCS-4B output is passed through inter-
nal diplexer, and approximately 2% of output power
reaches antenna. This mode used for diplexing
TCS-4B sweep onto a communication transmitter
signal. In DIRECT mode, TCS-4B output is con-
nected directly to the antenna bypassing diplexer,
and the communication transmitter input connection
on 4011 unit is open circuited.
A two-position toggle switch that selects trans-
UPPER FREQ
16.
mitter sweep range of either 2 to 16 or 2 to 30
16/30 Switch
MHz.
3-11
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |