NOTE
Early versions of the rechargeable battery supply - part number
6025-1018, Revision A - did not include a battery cutout pushbutton
switch (S1). Later versions - Revision B and on - include the cut-
out switch (S1) and a deep-discharge battery protection circuit that
prevents battery damage if the battery supply is accidentally left
on and allowed to discharge. The Revision A version of the battery
supply may suffer permanent damage, and cannot be recharged, if it
is allowed to completely discharge or if it is stored for long periods
without first being fully charged. Operating procedures for the
Revision A version of the rechargeable battery supply are the same as
for the non-rechargeable battery supply. However, the Revision A
rechargeable battery supply should be stored only after it is fully
charged. If difficulties or poor performance are encountered with
the Revision A battery supply, contact BR Communications for
assistance or repair.