TM 11-5820-890-30-5
16-17. REPLACEMENT OF FILTER EMI-CCA. Continued
ITEM
ACTION
REMARKS
INSTALLATION Continued
h. FILTER EMI-CCA wire
i.
Screw (19) and
Iockwasher (18)
Use soldering kit. Solder wires to correct
NOTE
terminals of FILTER EMI-CCA.
Before and after soldering,
clean wires and terminals
with cotton swabs and
alcohol.
Use cross tip screwdriver. Install and
hand tighten screw (19) and Iockwasher
(18) securing terminal lug (17) to FILTER
EMI-CCA.
j. Eight screws (5)
and Iockwashers (6)
Use cross tip screwdriver. Install and
If a screw is not stripped
hand tighten eight screws (5) and
but will not tighten, refer
Iockwashers (6) securing access
to paragraph 16-16 for
cover (1) to connector case (12).
replacement of its threaded
Use torque screwdriver. Torque
screw insert (if present).
screws to 8 to 10 in-lb.
If a tapped hole is defec-
tive, refer to paragraph
16-10 for replacement of
the connector case (12).
Section V. PREPARATION FOR STORAGE OR SHIPMENT
16-18. GENERAL INFORMATION.
Pack the electrical connector assembly (9A1) in an approved shipping container.
16-22
|