TM 11-5820-890-30-5
14-41. REPLACEMENT OF WIRING IN POWER SUPPLY ADAPTER CHASSIS (8A2). Continued
ITEM
ACTION
REMARKS
INSTALLATION Continued
j.
k.
l.
m.
Terminal post
Tiedown straps (11)
Rear access cover (2)
12 captive
screws (11)
Section V.
Use soldering kit, soldering aid, heat
Before and after soldering,
sink, and long nose pliers. Wrap and
clean wires and terminal
solder end of replacement wire on
post with alcohol and
terminal post.
cotton swabs.
Install replacement tiedown straps on wiring
harness, and remove wire tags.
Position replacement rear access cover on
the power supply adapter chassis. See
figure 14-7.
Use flat tip screwdriver. Install and hand
tighten the 12 captive screws securing
the rear access cover on the chassis.
Use torque screwdriver. Torque to 9 in-lb.
PREPARATION FOR STORAGE OR SHIPMENT
14-42. GENERAL INFORMATION.
a.
Pack the power supply adapter and any removed modules in approved shipping containers.
b.
All modules must be shipped enclosed in material that provides protection from static electricity. See
the following paragraph.
14-43. PACKING STATIC SENSITIVE MODULES.
The following steps should be followed when packing a static sensitive module for storage or shipment.
CAUTION
To avoid damaging static sensitive modules, use an antistatic pad on the work surface and wear
a grounded wrist strap when handling the module.
ITEM
ACTION
REMARKS
a. Module (1)
Place inside antistatic bag (2) or inside
antistatic wrapping material (3). See
figure 14-12.
b. Antistatic package (4)
Seal with adhesive tape. Attach
sensitive electronic devices unit
pack label (5).
c. Antistatic package (4)
Place inside approved shipping container (6).
Attach sensitive electronic devices
intermediate pack label (7).
14-76
|