TM 11-5820-890-30-5
7-14. REPLACEMENT OF FL2 FILTER. Continued
ITEM
ACTION
REMARKS
INSTALLATION Continued
m.
n.
o.
Filter mounting plate (22)
Position filter mounting plate (22) in
connector case (12).
Three screws (25),
Use cross tip screwdriver. Install and
Iockwashers (24),
tighten three screws (25), Iockwashers
and flat washers (23)
(24), and flat washers (23) securing
filter mounting plate (22) to connector
case (12).
Eight screws (5)
Use cross tip screwdriver. Install and
and Iockwashers (6)
hand tighten eight screws (5) and
Iockwashers (6) securing access
cover (1) to connector case (12).
Use torque screwdriver. Torque
screws to 8 to 10 in-lb.
7-15. REPLACEMENT OF WIRING.
Tools:
Diagonal cutting pliers
Wire stripper
Expendable supplies:
Solder
Alcohol
References:
Paragraph
Paragraph
Soldering kit
Cotton swabs
7-12 for removal and installation of J5 connector.
7-16 for removal and installation of threaded screw inserts.
If a screw is not stripped
but will not tighten, inspect
its tapped hole, If the tap-
ped hole is defective, refer
to paragraph 7-10 for re-
placement of connector
case (12).
If a screw is not stripped
but will not tighten, refer
to paragraph 7-16 for
replacement of its threaded
screw insert (if present).
If a tapped hole is defec-
tive, refer to paragraph
7-10 for replacement of
the connector case. (12).
ITEM
ACTION
REMARKS
REMOVAL
a. Eight screws (5) and
Use cross tip screwdriver. Remove and
Iockwashers (6)
inspect eight screws (5) and lockwash-
ers (6) securing access cover (1) to
connector case (12). If damaged,
obtain replacement. Lay access cover
to one side. See figure 7-2.
b. J5 connector (16)
7-16
Check wiring list and if applicable remove
connector J5 from connector case (12).
Inspect each screw and its
threaded screw insert (if
present) to determine if
any is defective. If a screw
is stripped, do not replace
its threaded screw insert.
If the holes are tapped,
there will be no threaded
screw insert.
Refer to paragraph 7-12
for removal instructions.
|