TM 11-5820-890-30-5
7-11. REPLACEMENT OF J1, J2, J3, OR J4 CONNECTOR. Continued
ITEM
ACTION
REMARKS
INSTALLATION Continued
f. Connector terminals
Use soldering kit and soldering aid.
NOTE
Solder wires to correct terminals of
Ensure each wire
connector. If necessary, slide
Iation sleeving on
insulation sleeving down over con-
if necessary, and
has insu-
it
nection, and apply heat to it until it
each wire is placed through
shrinks tight around the connection.
mounting hole in connector
case (12). While soldering
wires, attach heat sink to
bare wire between insula-
tion sleeving and terminal.
Before and after soldering,
clean wires and terminals
with cotton swabs
and alcohol.
g. Tiedown straps (13)
Replace any tiedown straps (13) that
were removed.
h. Eight screws (5)
Use cross tip screwdriver. Install and
and Iockwashers (6)
hand tighten eight screws (5) and
Iockwashers (6) securing access
cover (1) to connector case (12).
Use torque screwdriver. Torque
screws to 8 to 10 in-lb.
If a screw is not stripped
but will not tighten, refer
to paragraph 7-16 for
replacement of its threaded
screw insert (if present).
If a tapped hole is defec-
tive, refer to paragraph
7-10 for replacement of
the connector case. (12).
7-12. REPLACEMENT OF J5
Tools:
Flat tip screwdriver
Adjustable wrench
Expendable supplies:
Silicone compound
Alcohol
References:
CONNECTOR.
Soldering kit
Cotton swabs
Solder
Paragraph 7-16 for removal and installation of threaded screw inserts.
ITEM
ACTION
REMARKS
REMOVAL
a. Electrical connector
assembly (13A1)
Set on work surface with J5 connector
(16) toward you. See figure 7-2.
7-11
|