TM 11-5820-890-30-5
7-10. REPLACEMENT OF CONNECTOR CASE. Continued
ITEM
ACTION
REMARKS
INSTALLATION Continued
p. Screw (19) and
Iockwasher (18)
Use cross tip screwdriver. Install and
hand tighten screw (19) and Iockwasher
(18) securing E1 terminal lug (17) next
to filter mounting plate (22) or on
remaining hole of FILTER EMI-CCA.
q. J5 connector (16)
Position J5 connector (16) next to
mounting hole in connector case (12).
r. J5 connector (16) wires
Use soldering kit. Solder wires to correct
terminals of connector.
s. Tiedown strap (13)
t.
Neoprene gasket
u. Two screws (14)
(four screws for older
versions) and guide
pin (15)
V . Eight screws (5)
and Iockwashers (6)
Replace tiedown strap (13) if
removed.
Coat the neoprene gasket of J5
connector (16) with silicone com-
pound, and place the connector in
mounting hole of connector case (12).
Use flat tip (or cross tip) screwdriver
and adjustable wrench. Install and hand
tighten two (or four) screws (14) and
guide pin (15) securing J5 connector
(16) to connector case (12).
Use cross tip screwdriver. Install and
hand tighten eight screws (5) and
Iockwashers (6) securing access
cover (1) to connector case (12).
Use torque screwdriver. Torque
screws to 8 to 10 in-lb.
NOTE
Ensure each wire is placed
through mounting hole in
connector case (12).
Before and after soldering
clean wires and terminals
with cotton swabs and
alcohol.
7-9
|