TM 11-5820-890-30-5
Table 3-2, Test Adapter Continuity Checks Continued
1. SWITCH POSITIONS
2. DMM (+)
3. DMM (-)
4. RESULTS
5. FAULT
STIMULUS: 6
TP2
FCTN GEN
Greater than
CAL: FCTN GEN
- CC
100 k ohms
STIM SEL: FCTN GEN
STIMULUS: 6
TP2
FCTN GEN
Less than 1 ohm
CAL: MOD GEN
- CC
STIM SEL: FCTN GEN
STIMULUS: 6
TP2
FCTN GEN
Less than 1 ohm
CAL: OFF
- CC
STIM SEL: FCTN GEN
3-45
|