TROUBLESHOOTING GUIDES. Continued
3.2.
TS Guide 10. COMSEC ALARM NOT HEARD, OR WILL NOT CLEAR
(EXTERNAL DEVICE) Continued
ACTIONS
CHECKS
STEPS
NO:
Go to 10.15
CX-13292
10.14 Check installation of CX-13292
YES: Install cable and retry
improperly
and try to clear alarm
installed?
N/A
N/A
10.15 Remove VAA and set to LOCAL
N/A
N/A
Move HS to VAA J2/J3
N/A
N/A
Remove cable from MB J3/J4
Alarm clears?
YES: Go to 10.16
Reinstall VAA
NO:
Go to TS Guide 9
Short?
YES: Replace LS-671
10.16 Check continuity at LS-671 J1,
Pin A to Pin J
NO:
Replace CX-13292
N/A
Return to Operational Check
10.17 Connect HS to VAA J2/J3
TS Guide 11. VARIABLE (COMSEC OR FH DATA) WILL NOT LOAD
STEPS
CHECKS
ACTIONS
11.1 Replace fill cable with known
N/A
N/A
good fill cable
Load a variable
Variable loads?
YES:
Replaced fill cable is bad
NO:
Go to 11.2
11.2 Replace fill device battery with
N/A
N/A
known good fill device battery
Variable loads?
Load a variable
YES: Replaced battery is bad
NO:
Go to 11.3
11.3 Replace fill device with known
N/A
N/A
good fill device
Variable loads?
Load a variable
YES: Replaced fill device
is bad
NO:
Replace RT
316
|