3.1.
OPERATIONAL CHECK. Continued
Step 4. LOAD CHECKS
CHECKS
ACTIONS
STEPS
YES: Go to Step 4.2
SC frequencies
4.1 Load RT:
NO:
Replace RT
load properly?
Chan 1: 41000
Chan 2: 54000
Chan 3: 75000
YES: Go to Step 4.3
RT accepts fill?
4.2 Set RT MODE to FH
NO:
and load COMSEC
Go to TS Guide 11
and FH data*
I
I
Test sync time
YES: Go to Step 4.4
4.3 Load test sync time (82/09:36)
loads properly?
NO:
Replace RT.
I
YES: Go to Step 4.5
RT shuts down
4,4 Set RT to STBY
properly?
NO:
Replace RT
N/A
N/A
4.5 Set CB1 to OFF, wait 1 min.,
RT retains COMSEC,
YES: Go to STEP 5
and set CB1 to ON
FH, and SC data in FH
NO: Replace RT
Set FCTN to SQ ON
and SC modes?
*
NOTE: If using an Automated Net Control Device (ANCD), follow ICOM Fill procedure to load
COMSEC and FH data in all 6 channels. Otherwise, load COMSEC keys and FH data in
Channels 1,2, and 3.