2.2.
TROUBLESHOOTING GUIDES.
TS Guide 1. VARIABLE WILL NOT LOAD
ACTIONS
CHECKS
STEPS
Variable loads?
NO:
Go to 1.2
1.1
Replace fill cable with good one
and load a variable
YES: Replaced fill cable
is bad
Variable loads? NO:
Go to 1.3
1.2 Replace device btry with good one
YES: Replaced btry is bad
and load a variable
YES: Replaced fill device
Variable loads?
1.3 Replace fill device with good one
is bad
and load a variable
NO:
Replace RT
TS Guide 2. LOW OR NO POWER OUT
STEPS
CHECKS
ACTIONS
2.1
Note color of RT ANT J1
RT ANT J1
YES: Go to 2.2
Replace RT
Silver-colored?
NO:
2.2 Remove test set cable from RT ANT
Damaged
NO:
Go to 2.3
Visually Inspect RT ANT J1
RT ANT J1 ?
YES: Replace RT ANT J1
2.3 Set RT FCTN to LD
N/A
N/A
N/A
N/A
Place red probe on center of ANT J1
Place black probe on outside of J1
N/A
Read DMM
Read DMM while pressing center
YES: Replace RT
conductor of J1 in, with
drops more than
NO:
Replace RT ANT J1
red probe
2 Ohms?
25
|