TM  11-5820-890-20-2 2-21 2.2. TROUBLESHOOTING FLOWCHARTS. Continued CHART 1 VEHICLE MASTER CIRCUIT BREAKER TRIPS WHEN SET TO ON. (Sheet 10 of 12) NO YES CIRCUIT BREAKER TRIPS ? REPLACE MB POWER CABLE. 1.   CONNECT CX 13313 OR CX 13417 TO MB J3. 2.   IF PRESENT CONNECT CX 13417 TO MB J4. 3.   REMOVE POWER CABLE FROM MB J1. 4.   SET MASTER CIRCUIT BREAKER TO ON. 11 SH 12 NO YES CX 13292 CONNECTED TO MB J4 ? 12 SH 11 9 SH 10 NO YES CX 13303 CONNECTED TO MB J2 ? REPLACE MB. NOTE: Master circuit breaker in this case applies to that power circuit that supplies power to intercomm/communications system. This circuit is identified in vehicle instructions.