TM 11-5820-890-20-2
2-3
2.1.
OPERATIONAL CHECK. Continued
STEP 3. INTERCOM CHECK:
STEPS TO PERFORM
CHECKS TO MAKE
ACTIONS TO TAKE
3.1
At each control box, in turn
MONITOR to ALL
MONITOR to A
MONITOR to INT ONLY
MONITOR to C
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3.2
Press HS PTT and count into HS at each
MONITOR switch setting
AM 1780 relays click and
sidetone heard?
YES: Go to Step 3.3
NO:
Continue
At any position:
AM 1780 relays do not click
and sidetone not heard?
NO:
Continue
YES: Go to TS Chart 5
At any position:
AM 1780 relays do not click
and sidetone is heard?
NO:
Continue
YES: Go to TS Chart 6
At every position:
AM 1780 relays click
and sidetone not heard?
NO:
Continue
YES: Go to TS Chart 7
At a particular position:
AM 1780 relays click
and sidetone not heard?
NO:
Go to Step 3.3
YES: Go to TS Chart 8
3.3
Set commander's C 2298 MONITOR to C.
Connect HS to J803
Press HS PTT and count into HS
N/A
N/A
Sidetone heard?
N/A
N/A
YES: Go to Step 3.4
NO:
Go to TS Chart 9
3.4
Set all C 2298 MONITOR to INT ONLY.
Move HS to J802
N/A
N/A
N/A
Go to Step 3.5
3.5
Set C 2297 MONITOR to INT ONLY.
Move HS to J902
N/A
N/A
N/A
Go to Step 3.6
3.6
At each control box, press PTT and
count into HS
Sidetone heard?
YES: Go to STEP 4
NO:
Replace Control Box
|