TB 11–5820–890–20–2 6–3/(6–4 blank) 6.3. ECCM FILL DEVICE (MX 18290). a. If fill device will not accept a fill of FH data, troubleshoot as shown below. NO YES Fill Device Data Will Not Load. VARIABLES LOAD NO YES VARIABLES LOAD TROUBLESHOOTING FLOWCHART. 1.   REPLACE BATTERY WITH KNOWN GOOD BATTERY. 2.   LOAD A VARIABLE. 3.   TRANSFER THE VARIABLE TO A KNOWN GOOD RT. 1.   REPLACE FILL DEVICE CABLE. 2.   LOAD A VARIABLE. 3.   TRANSFER THE VARIABLE TO A KNOWN GOOD RT. PROPERLY DISPOSE OF THE REPLACED BATTERY. REPLACED FILL DEVICE CABLE IS BAD. REPLACE FILL DEVICE. START b. If fill device is faulty, send device to DS level maintenance for repair.