TM  11-5820-890-20-2 5-29 5.3. TROUBLESHOOTING FLOWCHARTS. Continued CHART 5 BATTERY TRAY DS1 DOES NOT LIGHT DURING TEST. (Sheet 1 of 3) NOTE: Make sure battery tray DS1 is set full CCW. B D E F A PSA J4 C START 1 SH 2 1.    SET PSA CB1 TO OFF. 2.    REMOVE CX 13290 CABLE FROM PSA J4. 3.    CHECK CONTINUITY AT PSA J4, PIN D TO PIN A (GND). NO YES SHORT TO GROUND ? REPLACE PSA. NO YES BATTERY TRAY DS1 LIGHTS ? 1.    REPLACE BATTERY TRAY DS1. 2.    PUSH BATTERY TRAY TEST S1 IN. REPLACED DS1 LAMP IS FAULTY.