TM 11-5820-890-20-2
5-5
5.2.
OPERATIONAL CHECK. Continued
OPERATIONAL CHECK FOR SRM
STEP 1. PREPARATION:
STEPS TO PERFORM
CHECKS TO MAKE
ACTIONS TO TAKE
1.1
Set RT:
FCTN to OFF
CHAN to 1
MODE to SC
RF PWR to HI
VOL to Mid Range
DIM to Full CW
COMSEC to Z
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
1.2
Set PSA: (MX 10862)
CB1 to OFF
DS1 to Full CCW
N/A
N/A
If LS 671 or VIC is used:
If neither is used:
N/A
N/A
Ensure PSA is set to REMOTE.
Ensure PSA is set to LOCAL.
1.3
Set LS 671:
CB1 to OFF
DS1 to Full CCW
VOL to OUT/Mid Range
N/A
N/A
N/A
N/A
N/A
N/A
1.4
Disconnect CX 13314 from
RT J4.
N/A
N/A
1.5
Handset (HS), H 250:
Connect to RT AUD/DATA J4
Ensure that HS used is operational
Install a known good HS
|