TM 11-5820-890-20-2
4-10
4.2.
TROUBLESHOOTING FLOWCHARTS. Continued
Z
Y
d
b
a
S
R
X
W
V
T
U
Q
P
N
M
L
K
J
F
E
D
C
B
A
G
H
J8(J7) OR J2
CHART 1
RCU DISPLAY READS OPEN" DURING SELF TEST.
(Sheet 6 of 8)
1. REMOVE RT VAA OR PSA FROM MB.
2. IF RT-A, THEN CHECK CONTINUITY AT RT
VAA E1A TO E2A.
3. IF RT-B, THEN CHECK CONTINUITY AT RT
VAA E1B TO E2B.
4. IF RT IS INSTALLED IN A PSA, THEN CHECK
CONTINUITY AT RT PSA E1 TO E2.
NO
YES
OPEN
?
REPLACE RT.
REPLACE VAA OR PSA.
NO
YES
OPEN
?
1. IF RT A, THEN CHECK CONTINUITY AT RT
VAA J8, PIN Y TO PIN a.
2. IF RT B, THEN CHECK CONTINUITY AT RT
VAA J7, PIN Y TO PIN a.
3. IF RT IS INSTALLED IN A PSA, THEN CHECK
CONTINUITY AT PSA J2, PIN Y TO PIN a.
REPLACE VAA OR PSA.
6