TM 11-5820-890-20-2
2-128
2.2.
TROUBLESHOOTING FLOWCHARTS. Continued
Chart 36
NO RT-A MODULATION FROM CREWMEMBER C 2298.
(Sheet 3 of 6)
D
E
F
G
P
N
M
L
B
C
H
J
K
A
V
U
T
S
R
P
N
M
L
K
J
H
F
E
D
C
B
A
NO
YES
22 TO 32
V dc
?
1. REMOVE CX 4723 FROM C 2298 J801/J804.
2. MEASURE VOLTAGE AT CX 4723,
PIN C TO PIN A (GND).
REPLACE CX 4723.
REPLACE C 2298.
NO
YES
22 TO 32
V dc
?
1. CONNECT CX 7060 TO HULL BENDIX
CONNECTOR.
2. REMOVE CX 7060 FROM TURRET BENDIX
CONNECTOR.
3. MEASURE VOLTAGE AT CX 7060,
PIN E TO PIN N (GND).
REPLACE CX 7060.
VEHICULAR WIRING IS
BAD.
5
SH 3
3
SH 3
CX 7060
CX 4723
|