TM  11-5820-890-20-2 2-111 2.2. TROUBLESHOOTING FLOWCHARTS. Continued Chart 31 RT-B WILL NOT KEY FROM COMMANDER'S C 2298. MONITOR SWITCH SET TO C. (Sheet 1 of 2) This step checks for an open in the commander's RT-B keying line. This voltage is present from a biasing circuit in the 1 watt audio board of the VAA. V U T S R P N M L K J H F E D C B A AM 1780 J504 V U T S R P N M L K J H F E D C B A 1.   CONNECT COMMANDER'S CX 4723 TO J504. 2.   REMOVE THE CX 4723 FROM C 2298 J801/J804. 3.   MEASURE VOLTAGE AT CX 4723, PIN F TO PIN A (GND). REPLACE COMMANDER'S C 2298. NO YES 1.0 TO 2.5 V dc ? REPLACE CX 4723. 1.   REMOVE COMMANDER'S CX 4723 FROM J504 OF AM 1780. 2.   MEASURE VOLTAGE AT AM 1780 J504, PIN F TO PIN A (GND). NO YES 1.0 TO 2.5 V dc ? 1 SH 2 START CX 4723