TM 11-5820-890-20-2
2-103
2.2.
TROUBLESHOOTING FLOWCHARTS. Continued
Chart 28
NO RT-A MONITORING AT COMMANDER'S C 2298.
MONITOR SWITCH AT A.
(Sheet 5 of 6)
V
U
T
S
R
P
N
M
L
K
J
H
F
E
D
C
B
A
CX 13313 P2
CX 13417 P1
V
U
T
S
R
P
N
M
L
K
J
H
F
E
D
C
B
A
MB J3
CX 13313 P1
CX 13417 J1, J2
NO
YES
SHORT
TO
GROUND
?
CHECK CONTINUITY AT MB J3,
PIN H TO J2, PIN A (GND).
1. REMOVE CX 13313 OR CX 13417 FROM
CX 13300.
2. CHECK CONTINUITY AT CX 13313 P1, PIN H
TO P2, PIN H OR CX 13417 P1, PIN H TO
J1/J2, PIN H.
NO
YES
OPEN
?
REPLACE MB.
6
SH 6
NO
YES
SHORT
TO
GROUND
?
REPLACE CX 13313 OR
CX 13417.
CHECK CONTINUITY AT CX 13313 OR CX 13417,
P1, PIN H TO P1, PIN A.
REPLACE CX 13313 OR
CX 13417.
NOTE:
If CX 13417 present, check
continuity at connector where
CX 13300 was connected.
5
SH 5
D
C
B
A
MB J2
|