TM  11-5820-890-20-2 2-46 2.2. TROUBLESHOOTING FLOWCHARTS. Continued Chart 10 AM 7239 DS1 IS NOT LIT. (Sheet 1 of 1) J H P K S R N M L F E D B A C V U T MB J5 NO YES DS1 LAMP LIT ? REPLACED LAMP IS BAD. REPLACE MB. 1.   SET VAA CB1 TO OFF. 2.   REMOVE VAA FROM MB. 3.   MEASURE VOLTAGE AT MB J5, PIN B TO PIN A (GND). NO YES 22 TO 32 V dc ? REPLACE VAA. 1.   REPLACE VAA DS1 LAMP. 2.   SET VAA CB1 TO ON. START