| TM 11-5820-890-10-8
RCU
BATTERY
RCU MAIN POWER
(BA-5590: Approximate Length of Expected Service; RF PWR in HI)
*
Operator usage rate is defined as 9 minutes of receiving/monitoring to every 1 minute of
transmitting, on average.
* * NCS usage rate is defined as 2 minutes of receiving/monitoring to every 1 minute of
transmitting, on average.
Manpack Radio/RCU Hold Up Battery (HUB)
8.3c.
Hold-up battery used is:
HUB
.
Battery, Non-Rechargeable (BA-5372/U)
BATTERY
MANPACK RADIO/RCU HUB BATTERY
(BA-5372: Approximate Length of Expected Service)
RT- 1523 Series
RCU
TYPE OF USE
6+ Mon
6+ Mon
Normal Back Up
SINCGARS HUB and ANCD batteries look similar and can be physically
interchanged. The HUB battery is 6.5 Volts while ANCD batteries are 3
Volts each. If HUB batteries (3 of them) are mistakenly placed in the
ANCD, it will be destroyed. Placing one ANCD battery in the RT HUB
position will cause the RT to lose its fill of data.
Therefore, be sure you know which battery goes where. Always read
the label before installing either HUB or ANCD batteries!