| TM 11-5820-890-10-8
8.2b.
PMCS for Control-Monitor (C-M)
PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR
SINCGARS
CONTROL-MONITOR
(Control-Monitor (C-M), C-11291/VRC Series)
Item
Item to
Operator
Not Fully Mission
Nr.
When
Check/Service
Procedure
Capable If:*
1
Before
CONTROLS:
During
RADIO
a.
Check for cracked
After
FCTN
or broken controls.
INIT
b.
Check for loose controls.
c.
DIM
Check for frozen controls.
d.
Check for missing control
knobs.
2
Before
CABLES:
a.
During
C-M Cable (CX-13290)
Check for presence.
After
b.
Check for proper
installation of cable.
Check for tightness
c
of connectors.
d.
Check for obvious
damage to cable.
3
Before
SELF-TEST:
Perform C-M self-test.
a.
b.
Test should result in "Gd."
4
Before
CONTROL OF
a.
Check control of RF PWR.
RT FUNCTIONS:
b.
Check control of RT
Mode.
c
Check control of Channel.
d.
Check control of
COMSEC.
*
The Control-Monitor is not essential to the operation of the SINCGARS radio with which it is
used. Problems found with the Control-Monitor during PMCS are corrected or reported to Unit
Maintenance, but they do not result in Not Fully Mission Capable determinations.