| TM 11-5820-890-10-8
6.3c.
Transfer Partial COMSEC/FH Data, ANCD to ANCD (Primary NCS Task 1)
DESCRIPTION
In addition to transferring complete SOI files, quick reference or full
SOIs, an NCS is expected to be able to transfer partial data loads. For
example, performance of this task enables the NCS to transfer specific
loadsets, Esets, COMSEC keys, TSKs, or sync time from one ANCD to
another, This capability facilitates dissemination within the unit when
less than total data is required. There are three options associated with
this task, allowing the NCS to perform selected special functions.
NCS personnel perform the actions required in each subtask. in the
DETAILED FLOWCHART
order shown. Results are shown as ANCD displays (dark bordered
boxes), or as RT displays in the form of "RT display shows." Where
appropriate, results are expressed as explanations of occurrences.
TRANSFER PARTIAL COMSEC/FH DATA, ANCD TO ANCD
RESULTS
SUBTASKS
ACTIONS
(1) Turn ANCD ON
a.
Prepare Source ANCD for
select.
partial data transfer*
Soi Radio sUpervisor
Send Receive Database
(2) Enter RADIO
sEtup Comsec Time
send to:
Enter SEND
(3)
Radio Ancd Stu PC
Loadset** Database Time**
(4) Enter ANCD
Key** Eset** Mwod***
select: Loadset
(5) Enter LOADSET
(name) ENTR
Do you want to include time?
(6) Scroll (PgUP/PgDN) to
loadset desired, ENTR
(Y/N)
Connect to ANCD and press
(7)
Respond YES (unless you
[SEND] (WAIT)****
want to omit time)
6-7
|