| TM
11-5820-890-10-8
5.6.
SPECIAL OPERATOR TASKS (SlP/ASIP)
In addition to the eight special operator tasks, there are two Special
GENERAL
SIP/ASIP Operator Tasks. These special SlP/ASlP related tasks use the
SIP/ASIP RT as an RCU; and send data from one computer to another
over a SINCGARS secure, frequency hopping net using RS-232
enhanced data feature.
Use SIP/ASIP RT as an RCU (Special Operator Task 9)
5.6a.
RESULT
ACTION
STEP
Prepares SIP/ASIP RT and RCU(RT) for
Ensure SIP/ASIP RT and RCU(RT) are
1
remote operations*
loaded
install two-wire kink from RCU(RT)** to
2
N/A
remoted radio
This enables the RCU(RT) to control the
Set remoted radio FCTN switch to the
3
remoted radio
REM position
(NOTE: FCTN positions LD, SQ OFF,
4
Set RCU(RT) FCTN switch to SQ ON
and RXMT may also be used)
Set RCU(RT) DATA to any position
5
N/A
"LD", "LDE", "RT", "RCU", and "EXT"
Press "RCU" key on RCU(RT); and
6
options appear in the display (For ASIP,
select the RCU option
"EXT" is not shown.)
The SIP/ASIP RT is now ready to
Wait for 7 seconds; then note when
7
perform as an RCU(RT)
RCU(RT) display blinks
This enables the RCU(RT) operator to
Set RCU(RT) FCTN switch to the REM
8
call the REM radio operator by wire
positron***
Producing ring tone and CALL message
Press RCU(RT) CALL key and PTT at
9
at REM RT; operators can now talk via
same time for 4-7 seconds
orderwire (not secure)
REM radio is now controlled by the
Set RCU(RT) to SQ ON
10
RCU(RT)
*
For use of a SIP RT as either a manpack RCU or a manpack remoted radio, Battery Box
CY-8523A/B is required. Battery Box CY-8523C cannot be used for manpack remote
operations, ASIP RT requires a two-wire adapter.
* * The Control, Receiver-Transmitter (RCU), C-11561, may continue to be used for remote
control of a SINCGARS SIP radio when used for voice and SINCGARS data modes. It cannot be
used for enhanced data modes.
*** RCU(RT) COMSEC must be set to PT to talk on orderwire.
5-62
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |