5.5f.
Perform Cold Start Net Opening (Special Operator Task 3)
DESCRIPTION
Operators will be required to perform this special task only if the NCS
elects to use the Cold Start net opening procedure. Hot Start is the
more commonly used net opening procedure. Cold Start procedures
require operators to load their radios with COMSEC keys and FH data,
stand by at the prescribed time, communicate with the NCS on the
MAN channel, set RT FCTN to LD, note when ERF is received, and
press STO and channel number to retain data. Any failure in the ERF
process prevents the operator concerned from communicating in the
frequency hopping mode. Because the Cold Start procedure is more
demanding in coordination and operator requirements, units normally
use the Hot Start procedure.
DETAILED FLOWCHART
SUBTASKS
ACTIONS
RESULTS
a.
Prepare radio to receive
(1) Load MAN (SC)
(See Primary Operator Task 1)
an ERF
frequency into RT
(2)
Load RT with required
(See Primary Operator Task 2)
COMSEC/FH data
(3)
Set FCTN to LD
N/A
(4)
Set COMSEC to CT*
N/A
(5)
Set CHAN to MAN
Display shows "COLD" (ready to
receive an ERF)
(6)
Set MODE to FH
N/A
b. Receive and store ERF
(1) Standby until NCS
N/A
sends the ERF
(2)
Note signal display
Display shows "HF XXX"
activate
Display shows "STO _"
(3) Press STO
Display shows channel entered
(4) Press X (1-6)