CONTROL-MONITOR CONTROLS AND USES
CONTROL
PURPOSE
RADIO
This control is used to select Radio 1, 2, or 3. Positions 1 and 2 are for
RT-A and RT-B in first VAA; position 3 is for RT-A in second VA4
FCTN
This control is used for selecting test, RF power, RT mode, channel,
(Function)
COMSEC variable, COMSEC mode, and main or standby status.
TEST
Used to run C-M self-test. Results are shown in displays. Self-test will
continue until FCTN switch is moved out of TEST position.
RF
This control position is used to set the RF power output of the radio.
(Radio Frequency)
The INIT switch is used for adjusting power.
RT MODE
Used to set RT mode, including power off. INIT switch is used to make
changes. RT mode display shows operating mode.
CHAN
Used to select RT channel, including CUE and MAN. Channel display
shows channel selected; with "0" for MAN and "C" for CUE.
(Channel)
VAR
Used to select COMSEC keys.
(Variable)
COMSEC
Used to select COMSEC mode, plain text or cipher text. COMSEC
display shows PT or CT.
CONTROL
Used to change C-M from standby (S) to main (M). INIT switch is used
to make changes. Control display shows operating condition.
INIT
Used with FCTN switch to change functions of RT and C-M. Moving INIT
(Initiate)
switch up moves FCTN display to right, or increases channel number.
Moving INIT switch down moves FCTN display to left, or decreases the
channel number.
DIM
This control adjusts brightness of displays. Turning it clockwise
bnghtens displays; counterclockwise dims displays. DIM control is
turned fully counterclockwise for use of night vision goggles.