Table 3-2. Radio Set Minimum Performance Test--Continued
3-7. Fault Isotation Test
Figure 3-4 and 3-6 show the equipment setups necessary
to perform the fault isolation tests.
Table 3-3 is a fault isotation test for the radio set. By us-
ing these tests and the associated test equipment, the
3-9. Test Point Locations
radio set may be fault isolated to a defective module. If
Figures 3-7 and 3-8 show the test point locations used in
the problem cannot be located to a defective module or
fault isolation testing. Test point connections are made
other DS level maintenance, then higher level mainte-
by a special rf cable assembly 565461-801 (part of Main-
nance is required. In all cases, after a defective module
tenance Kit MK-( ) /PRC-68). In all cases where this
has been replaced or a repair made to the radio set, the
minimum performance test (table 32), or minimum per-
cable is used, the center conductor is connected to the
formance check using the test set (table 2-4), must be
test point called for, and the shield is connected to the
performed to ensure the radio set is fully operational.
nearest ground point on the printed circuit board. The
BNC connector end mates with the applicable test
3-8. Fault Isolation Test Equipment Set-
equipment unit, when called for.
ups