Table 4-2. Checkout/Troubleshoot the Receiver-Transmitter RT-1277/URC-92--Continued 
STEP 
ACTION 
INDICATION 
NEXT STEP 
190 
Check switches 1A1S7, 1A1S8, 1A1S1 and 
Switches check good. 
Yes: step 292 
1A1S2. 
No: replace faulty switch 
191 
Check FREQ CONTROL switch 1A1S15. 
Switch checks good. 
Yes: step 192 
No: replace switch 
1A1S15 
192 
Set mode switch to LSB. Check frequency switch 
Components check good. 
Yes: step 193 
and associated diode related to faulty indication 
No: step 274 
in step 167. (Refer to FO-10). 
193 
Remove Translation CCA 1A4A3. Connect fre- 
Frequency checks are correct. 
Yes: step 194 
quency counter to 1A4XA2J2-1. Perform fre- 
No: step 201 
qeuncy checks as shown below. 
Frequency Checks 
Frequency Switch Settings 
10 KHz 
1 KHz 
100 Hz 
Frequency 
0 
0 
1 
1.5001 MHz 
0 
0 
2 
1.5002MHz 
0 
0 
3 
1.5003 MHz 
0 
0 
4 
1.5004 MHz 
0 
0 
5 
1.5005 MHz 
0 
0 
6 
1.5006MHz 
0 
0 
7 
1.5007MHz 
0 
0 
8 
1.5008 MHz 
0 
0 
9 
1.5009 MHz 
Frequency Switch Settings 
10 KHz 
1 KHz 
100 Hz 
Frequency 
0 
1 
0 
1.5010 MHz 
0 
2 
0 
1.5020 MHz 
0 
3 
0 
1.5030 MHz 
0 
4 
0 
1.5040 MHz 
0 
5 
0 
1.5050 MHz 
0 
6 
0 
1.5060 MHz 
0 
7 
0 
1.5070 MHz 
0 
8 
0 
1.5080 MHz 
0 
9 
0 
1.5090 MHz 
Frequency Switch Settings 
10 KHz 
1 KHz 
100 Hz 
Frequency 
1 
0 
0 
1.5100 MHz 
2 
0 
0 
1.5200 MHz 
3 
0 
0 
1.5300 MHz 
4 
0 
0 
1.5400 MHz 
5 
0 
0 
1.5500 MHz 
6 
0 
0 
1.5600 MHz 
7 
0 
0 
1.5700 MHz 
8 
0 
0 
1.5800MHz 
9 
0 
0 
1.5900 MHz 
194 
Connect signal generator to 1A4A6-E17 using 50 ohm coaxial 
Multimeter indicates more than + 4.5 VDC. 
Yes: step 195 
cable. Connect multimeter between 1A4A4-TP1 and ground. 
No: step 199 
Set signal generator frequency to 9.9 MHz, output level to 0.1 V, 
RMS. Set 10 MHz, 1 MHz, and 100 KHz switches to 0. 
195 
Slowly increase signal generator frequency. 
At 10.0 MHz, multimeter indication changes to less 
Yes: step 196 
than + 0.9 VDC. 
No: step 299 
196 
Using a multimeter between ground and pin indicated, and by 
In each case, multimeter indicates greater than + 4.5 
Yes: step 197 
varying the frequency above and below the indicated transition 
VDC with signal generator below the transition 
No: step 202 
frequency, perform frequency switch checks as shown below. 
frequency, and less than + 0.9 VDC with signal 
generator above the transition frequency. 
Frequency Checks 
Frequency Switch Settings 
Transition 
10MHz 
1 MHz 
100 KHz 
Frequency ( 1 
KHz) 
0 
0 
1 
10.1 MHz 
0 
0 
2 
10.2 MHz 
4-15 
 | 
| 
 