Click here to make tpub.com your Home Page

Page Title: Table 4-2. Checkout/Troubleshoot the Receiver-Transmitter RT-1277/URC-92 (cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5820-873-34
Table 4-2.
Checkout/Troubleshoot the Receiver-Transmitter RT-1277/URC-92--Continued
STEP
ACTION
INDICATION
NEXT STEP
26
Connect multimeter between 1A1S16-7 and ground.
Multimeter indicates + 12 VDC 0.8 VDC.
Yes: replace 1A1S16
No: step 285
27
Set mode switch to OFF.  Remove 1A6A1 from 1A6XA1.
Continuity checks good.
Yes: step 28
Check continuity between 1A6XA1 pins C and 3.
No: replace transformer
1A6T1.
28
Continuity check 1A6TB1 pins E1 to E3, and pins E5 to E6.
Continuity checks good.
Yes: step 285
No: replace transformer
1A6T1.
29
Connect multimeter between 1A6XA1-15 and ground.
Multimeter indicates + 5 VDC 0.25 VDC.
Yes: step 31
No: step 32
30
Connect multimeter between 1A1S16-3 and ground.
Multimeter indicates + 5 VDC 0.25 VDC.
Yes: step 31
No: step 36
31
Connect multimeter between 1A1DS3 center contact and
Multimeter indicates + 5 VDC 0.25 VDC.
Yes: replace 1A1DS3
ground.
No: step 285
32
Connect multimeter between 1A6XA1-P and ground.
Multimeter indicates + 12 VDC 0.8 VDC.
Yes: step 33
No: step 35
Yes: step 34
33
Check transistor 1A6Q103.
Transistor 1A6Q103 checks good.
No: replace transistor
1A6Q103
34
Check fuse 1A6A1F3.
Fuse checks good.
Yes: step 286
No: replace fuse 1A6A1F3
35
Set mode switch to OFF.  Remove 1A6XA1 from 1A6A1.
Continuity checks good.
Yes: step 36
Continuity checks 1A6XA11 pin P to pin 13.
No: replace transformer
1A6T1
36
Check components 1A1Q101, 1A1C5, and 1A1C7.
Components check good.
Yes: step 37
No: replace faulty com-
ponent.
37
Connect multimeter between 1A1S16-3 and ground.
Multimeter indicates + 5 VDC 0.25 VDC.
Yes: step 39
No: step 38
38
Connect multimeter between 1A6A1F3 and A6A1C9 junction
Multimeter indicates + 10 to + 22 VDC.
Yes: step 285
and ground.
No: step 286
39
Connect multimeter between 1A1A3P1-44 and ground.
Multimeter indicates + 5 VDC 0.25 VDC.
Yes: step 288
No: step 40
40
Connect multimeter between 1A1A2-1 and ground.
Multimeter indicates + 5 VDC 0.25 VDC.
Yes: step 289
No: step 41
41
Connect multimeter between 1A1S16-4 and ground.
Multimeter indicates + 5 VDC 0.25 VDC.
Yes: step 285
No: replace switch
1A1S16
42
Connect multimeter between 1A1S16-2 and ground.
Multimeter indicates + 3 VDC 0.25 VDC.
Yes: step 43
No: replace switch 1A1S16
43
Check components 1A1CRF53. lA1CR54, and 1A1CR55.
Components check good.
Yes: step 285
No: replace faulty com
ponent.
44
Connect multimeter between 1A1DS1-1 center contact and
Multimeter indicates + 12 VDC 0.8 VDC.
Yes: replace 1A1DS1
ground.
No: step 45
45
Connect multimeter between 1A1S1A, rear, pin 4 and ground.
Multimeter indicates + 12 VDC 0.8 VDC.
Yes: step 46
No: step 48
46
Connect multimeter between 1A1S2C, rear, pin 4 and ground.
Multimeter indicates + 12 VDC 0.8 VDC.
Yes: step 47
No: step 49
Yes: step 48
47
Check diode 1A1CR16.
1A1CR16 checks good.
No: replace diode
1A1CR16
Yes: step 49
48
Check switch 1A1S15.
1A1S15 checks good.
No: replace switch
1A1S15
Yes: step 52
No:
replace
faulty
49
Check switches 1A1SlA rear, 1A1S2C rear, and 1A 1S3B rear.
Components check good.
component.
50
Set FREQ CONTROL switch to B.  Set FREQUENCY B
LOW FREQ LIMIT lamp illuminates sometimes.
Yes: step 52
controls to 1.5000 MHz. Rotate 100 KHz control thru positions
No: replace switch 1A1S9
4, 3, 2, 1 and 0.
51
Check the following components 1A1S7A rear, 1A1S8C rear,
Component d check good.
Yes: step 285
1A1S9B rear, 1A1S15 and 1A1CR37.
No:
replace
faulty
component.
4-6