Page Title: Table 3-2 Checkout/Troubleshoot the Receiver-Transmitter RT-1277/URC-92-Continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home

   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 



TM 11-5820-873-34
Table 3-2 Checkout/Troubleshoot the Receiver-Transmitter RT-1277/URC-92-Continued
STEP
ACTION
INDICATION
NEXT STEP
79
Connect oscilloscope to 1A4XA4J4-B, ground
Oscilloscope displays waveform similar to Fig
Yes: step 142
lead to ground.
3-2K.
No: step 83
80
Connect oscilloscope probe to 1A4XA1J1-18,
Oscilloscope displays waveform similar to Fig
Yes: step 132
ground to lead ground.
3-2H.
No: step 138
81
Connect VTVM (ACO 1A4XA1J1-6, ground lead
VTVM indicates 09 V peak-to-peak minimum.
Yes step 132
to ground.
No: step 138
82
Connect oscilloscope probe to 1A4XA1J1-17,
Oscilloscope displays waveform similar to Fig
Yes: step132
ground lead to ground.
3-2J.
No: step 138
83
Connect oscilloscope to 1A4XA3J3-15, ground
Oscilloscope displays waveform similar to Fig
Yes: step 132
lead to ground.
3-2L.
No: step 139
84
Replace Sideband Generator CCA with known
Oscilloscope displays waveform similar to Fig
Yes: step 134
good Sideband Generator CCA Key microphone.
3-2A, less than 2 V peak-to-peak maximum.
No: step 132
85
Connect multimeter between 1A3XA3J3-17 and
Multimeter indicates less than +1.6VDC.
Yes: step 86
ground.
No: step 132
86
Connect frequency counter to 1A3XA2J2-1.
Frequency counter indicates 10.5 MHz.
Yes: step 136
No: step 87
87
Connect frequency counter to 1A3XA3J3- 1.
Frequency counter indicates 10.5 MHz.
Yes: step 132
No: step 134
88
Connect multimeter between 1A3A5-E11 and
Multimeter indicates + 12 VDC 0.8 VDC.
Yes: step 89
ground.
No: step 132
89
Connect multimeter between 1A3A5XA2J2-6
Multimeter indicates + 12 VDC 0.8 VDC.
Yes: step 90
and ground.
No: step 132
90
Connect multimeter between 1A3A5XA3J3-5
Multimeter indicates + 12 VDC 0.8 VDC.
Yes: step 91
and ground.
No: step 132
91
Connect frequency counter to 1A3A5XA2J2-1,
Frequency counter indicates 10.5 MHz.
Yes: step 136
ground lead to ground.
No: step 134
92
Remove Translator CCA 1A4A3 Connect fre-
Frequency checks are correct.
Yes: step 93
quency counter to 1A4XA2J2-1. Perform fre-
No: step 97
quency checks as shown below.
Frequency Checks
Frequency Switch Settings
10 KHz
1 KHz
100 Hz
FREQUENCY
0
0
1
1.5001 MHz
0
0
2
1.5002 MHz
0
0
3
1.5003 MHz
0
0
4
1.5004 MHz
0
0
5
1.5005 MHz
0
0
6
1.5006 MHz
0
0
7
1.5007 MHz
0
0
8
1.5008 MHz
0
0
9
1.5009MHz
10 KHz
1 KHz
100 Hz
FREQUENCY
0
1
0
1.5010 MHz
0
2
0
1.5020 MHz
0
3
0
1.5030 MHz
0
4
0
1.5040 MHz
0
5
0
1.5050 MHz
0
6
0
1.5060 MHz
0
7
0
1.5070 MHz
0
8
0
1.5080 MHz
0
9
0
1.5090 MHz
10 KHz
1 KHz
100 Hz
FREQUENCY
1
0
0
1.5100 MHz
2
0
0
1.5200 MHz
3
0
0
1.5300 MHz
4
0
0
1.5400 MHz
5
0
0
1.5500 MHz
6
0
0
1.5600 MHz
7
0
0
1.5700 MHz
8
0
0
1.5800 MHz
9
0
0
1.5900 MHz