Table 5-3. Radio Receiver-Transmitter RT-980/GRC-171 Performance Tests (Sheet 8 of 17)
CONTROL SETTINGS
OPERATION OF TEST
AND OPERATION
PERFORMANCE
STEP
EQUIPMENT
POINT OF TEST
OF EQUIPMENT
STANDARD
IF OUTPUT
35
Connect equipment as
IF output
Set REMOTE/LOCAL
5 to 15 mV.
shown in figure 5-3.
(A10A2J8)
switch to LOCAL,
Set rf signal generator
PTT/CARRIER TEST
for rf output level of
switch to PTT,
6 V at 300.000 MHz.
SQUELCH switch to
OFF, and frequency
switches to 300.000
MHz. Measure the
IF output voltage.
RECEIVER IMAGE RESPONSE
36
Connect equipment as
IF AGC
Set REMOTE/LOCAL
This measurement will
shown in figure 5-4.
(A10A1TP12)
switch to LOCAL,
be a reference for
Set rf signal generator
PTT/CARRIER TEST
measurements taken
for rf output level of
switch to PTT,
in step 37.
6 V at 399.975 MHz.
SQUELCH switch to
OFF, and frequency
switches to 399.975
MHz. Measure and
note IF AGC
(A10A1TP12)
voltage.
37
Adjust rf signal generator
Same as step 36.
More positive than
for 339.975 MHz with
Observe and com-
reference voltage.
60,000-V rf output.
pare the IF AGC
voltage with ref-
erence voltage
determined in
step 36.
NOISE BLANKER
NOTE
The oscilloscope can be used as an aid in setting up the pulse generator pulse width
and pulse recurrence frequency. Noise blanker operation can be observed with the
oscilloscope connected to the RT-980/GRC-171 AUDIO OUTPUT (A10A2J22-N/S).