| TO 31R2-2GRC171-2
TM 11-5820-815-14
NAVELEX 0967-LP-544-5010
Table 1-4. Equipment Required But Not Supplied (Sheet 6 of 6)
OFFICIAL
COMMON
PART NO OR
MAINT
NOMEN
NAME
MFR MODEL NO
PURPOSE AND DESCRIPTION
LEVEL
AN/USM-216
Digital multimeter
Provides method of measuring
D
the d/a servo amplifier module
digital-to-analog converter
circuit voltages with an
accuracy exceeding 0.025%.
Power oscillator
AILTECH 445
Provides an adjustable rf
D
power source for testing and
alignment of the rf filter
module.
Uhf plug-in head
AILTECH 186
Provides means to operate the
D
power oscillator AILTECH 445
in the uhf range with power
output up to 35 watts.
50-ohm coupling
General Radio
Provides means of coupling
D
capacitor
874K
signal and blocking dc voltage
during rf filter receiver
attenuation test.
Maintenance level abbreviations:
O - organization
I - intermediate
D - depot