| TM 11-5820-695-35
(4) Adjust the incident wave voltage step to
coincide with the center screen graticule line of the
oscilloscope using the VERT POSITION control.
(1) Connect the two elbow adapters to bridge
(5) Remove the 50 ohm termination and
the STEP OUTPUT jack to the SIGNAL IN jack on the
insert the calibrated 1.1 VSWR mismatch (Mecca model
front panel of the reflectometer, and connect the
400-1.10). Note the upward deflection point on the
GR874-to-N adaptor and the UG-29B/U adaptor to the
oscilloscope, this represents an SWR of 1.1. Therefore,
SIGNAL OUT jack on the front panel of the
the increments between the 50 ohm terminated center
reflectometer.
scale and the 1.1 SWR calibrated line indicate values of
(2) Place POWER switch to ON and set the controls on
SWR between the nominal SWR of the 50 ohm
the reflectometer to the following positions:
termination (typically 1.05 residual SWR) and the
calibrated 1.1 SWR reference line. The 1.1 SWR
Control
Position
reference point can be adjusted to some convenient
OM LINE/OM DISLAY ---------------- 20
graticule line using the VERNIER CAL adjust (inner
MAGNIFIER ------------------------------ 6
control of the REFL COEFFICIENT controls).
MAGNIFIER DELAY . ------------------ 4
REFL COEFFICIENT ------------------- 0.5
SWEEP ------------------------------- NORMAL
(6) Remove the calibrated mismatch from the
SIGNAL OUT jack and connect the coaxial cable to be
tested to the SIGNAL OUT jack using the adaptor
(3) Connect 50 ohm termination HP-908A to
GR874B-toOSM J. Observe the oscilloscope to
the SIGNAL OUT Jack using the adapters installed in
determine if the coaxial cable being tested meets the
step (1).
1.1 VSWR criteria.
4-10
|