| TM 11-5820-695-35
d. Procedure.
Control setting
Step .
Test Equipment
Equipment under Test
Test procedure
Performance Standard
No.
1.
AN/USM-161
N/A
a.
Remove Dummy load Electrical
a. None.
POWER RANGE
DA-541/GRCfrom Adapter,
10 MW
Waveguide UG-1883/GRC.
+ 10 DBM
b.
Connect the equipment as shown in b. None.
POWER: 1.0
figure 3-29.
BIAS-READ: READ
c.
Set Switch, Waveguide
c
None.
COMP ATTENUATOR: 0
SA-1679/GRC to the TO LOAD
(TEST) position.
d.
Set the controls on radio frequency
d. None.
bandpass filter 1FL3 and electrical
frequency synthesizer 1A14 to
4400.0 MHz.
e.
Calculate the calibration plate
e . T-1054(P/GRC-I44(V) output
correction factors for both
as indicated on AN/JSM-161 shall
CG-2514/U. And the CG-251/U
be 150 milliwatts minimum.
Algebraically add the
correction factors .If the sum of
the correction factors is between
-2.2 db and +2.2 db; set the
COMP ATTENUATOR dial on
the AN/USM-161 for the com-
puted correction factor and read
the outermost scale on the
POWER control indicator, after
it is adjusted for a null indication
on the NULL INDICATOR
meter .Multiply this indication by
1000 to obtain the
T-1054(p)/GRC-144(V)-output power in
milliwatts. If the computed
correction factor is not between
2.2 db, refer to TM
11-6625-498-12 to determine the
AN/USM-161 power indication.
2. Same as step 1.
N/A
a
a. None.
bandpass filter 1FL3 and electrical
frequency synthesizer 1A14 to
4700.0 MHz.
b.
Same as step 1e.
b. Same as step 1e.
3. Same as step 1.
N/A
a.
Set the controls on radio frequency
a. None.
bandpass filter 1FL3 and electrical-
frequency synthesizer 1A14 to
5000.0 MHz.
b.
Same as step 1e.
b. Same as step 1e.
3-73.
R-1467(P)/GRC-144(V) and
R-1467(P)A/GRC-144(V) Frequency
(3) TNC male to BNC female adapter (part of Meter
Accuracy Test
Calibration Facilities Kit MK-1207/GRC).
b. Test Connections and Conditions. Record the R-
a.
Test Equipment and Materials.
1467(P)/GRC -1440) operating frequency.
(1) Counter Electronic, Digital Readout AN/USM-207.
207 (TM 11762500-10) and allow a 15minute warmup period.
(2) Selector Adapter, type 50-177-6801 (part of Meter
Calibration Facilities Kit MK-1207/GRC).
Change 6
3-91
|