TM 11-5820-695-35
144(V) troubleshooting chart (b below) supplements the
3.18.1. Converter Multiplier CV-3633/GRC 144(V)
operational checks and corrective measures contained
Troubleshooting Chart
in TM-11-5820-695-12. If the operational checks and
corrective  measures  in  below)  supplements  the
WARNING
operational TM-11-5820-695-12 fail to correct the
trouble or indicates that higher category maintenance is
115 Vac is present in Converter-
required, apply the corrective action in the chart below.
Multiplier CV-3633/GRC-144(V).  Do
To use the chart, read down the Symptom column of the
not remove or replace parts, nor
troubleshooting chart until the abnormal symptom or
perform  continuity  or  resistance
condition is found.  Perform the corrective actions
checks  while  primary  power  is
indicated in the chart until the abnormal symptom or
applied  to  Radio  Set  AN/GRC-
condition is corrected.
144(V)4.
Figure 3-25.1 is a parts location diagram which will aid
a.
Use of the Chart.
The CV-3633/ GRC-
the maintenance person in locating parts.
b.
Converter-Multiplier CV-3633/GRC-144(V) Troubleshooting Chart.
Item No.
Symptom
Probable trouble
Corrective actions
1
POWER 1.5 AMP-SLO
a.
Defective component or
a.
Remove amplifier-
BLO fuse blows
wire in primary power
multiplier 3A5 (TM
when replaced.
distribution circuits or
11-5820-695-12)
amplifier-multiplier 3A5.
from electrical
equipment chassis
3A7. Insert re-
placement fuse and
then set POWER ON/
OFF switch on
status panel 3A8 to
ON. If replacement
fuse blows, proceed
to step b below.
Otherwise proceed
to c and d below to
isolate the fault.
b.
Defective electrical
b.
Perform the CV-
equipment chassis 3A7.
3633/GRC-144(V)
primary power dis-
tribution checks
(para 3-18.2c
sections 3a, b
and c).
c.
Defective component or
c.
Use the TS-352B/U
wire An amplifier mul-
to check amplifier-
tiplier 3A5.
multiplier 3A5
wiring.
d.
Defective amplifier-
d.
Use the TS-352B/U
multiplier heater HR1.
to check its resis-
tance as follows:
3A5P1 pin 1 to pin
2 should be 176 +18
ohms.
Change 6 3-30.1